Data Sheet

Product Specification
Ver 1.2 41 / 43
pattern will be adjusted to 60,RH=35% and storage period
is 30 minutes. After 30 minutes, it needs 30min to let
temperature rise to -25. One temperature cycle
(2hrs) is complete.
2. Temperature cycle repeats 70 times.
3. When 70 cycles finished, the samples will be taken out
from experiment chamber and set aside a few minutes.
As EPDs return to room temperature, tests will
observe the appearance, and test electrical and optical
performance based on standard # IEC 60068-2-14NB.
performance
standards.
8
UV exposure
Resistance
765 W/m
2
for 168
hrs,40
Standard # IEC 60068-2-5 Sa
9
Electrostatic
discharge
Machine
model:+/- 250V,
0Ω, 200pF
Standard # IEC61000-4-2
10
Package
Vibration
1.04G,Frequency :
10~500Hz
Direction : X,Y,Z
Duration:1hours
in each direction
Full packed for shipment
11
Package Drop
Impact
Drop from height
of 122 cm on
Concrete surface
Drop sequence:1
corner, 3edges,
6face
One drop for
each.
Full packed for shipment
Actual EMC level to be measured on customer application.
Note: (1) The protective film must be removed before temperature test.
(2) In order to make sure the display module can provide the best display quality, the update should be made after putting the display
module in stable temperature environment for 15 mins.
(3) There’s temperature vs display quality limitation in our display module, we guarantee 1pixel display quality from 5~30, and
2 pixel display quality for 0~5 & 30~40.
.
2.7" e-Paper (B)