Data Sheet

www.waveshare.com
1740
21) XON LUT (LUTXON) (R29H)
Action
W/R
C/D
D7
D6
D5
D4
D3
D2
D1
D0
Build Look-Up Table
for XON (201-byte
command, bytes 2~11
repeated 20 times)
0
0
0
0
1
0
1
0
0
1
This command builds LUTXON.
22) PLL Control (PLL) (R30H)
Action
W/R
C/D
D7
D6
D5
D4
D3
D2
D1
D0
Controlling PLL
0
0
0
0
1
1
0
0
0
0
0
1
-
-
M[2:0]
N[2:0]
The command controls the PLL clock frequency. The PLL structure must support the following frame rates:
M
N
Frame Rate
M
N
Frame Rate
M
N
Frame Rate
M
N
Frame Rate
1
1
29 Hz
3
1
86 Hz
5
1
143Hz
7
1
200 Hz
2
14 Hz
2
43 Hz
2
71 Hz
2
100 Hz
3
10 Hz
3
29 Hz
3
48 Hz
3
67 Hz
4
5 Hz
4
21 Hz
4
36 Hz
4
50 Hz (Default)
5
7 Hz
5
17 Hz
5
29 Hz
5
40 Hz
6
6 Hz
6
14 Hz
6
24 Hz
6
33Hz
7
5 Hz
7
12Hz
7
20 Hz
7
29 Hz
2
1
57 Hz
4
1
114 Hz
6
1
171 Hz
2
29 Hz
2
57 Hz
2
86 Hz
3
19 Hz
3
38 Hz
3
57 Hz
4
14 Hz
4
29Hz
4
43 Hz
5
11 Hz
5
23 Hz
5
34 Hz
6
10 Hz
6
19 Hz
6
29 Hz
7
8 Hz
7
16 Hz
7
24 Hz
23) Temperature Sensor Calibration(TSC) (R40H)
Action
W/R
C/D
D7
D6
D5
D4
D3
D2
D1
D0
Sensing Temperature
0
0
0
1
0
0
0
0
0
0
1
1
D10
D9/TS7
D8/TS6
D7/TS5
D6/TS4
D5/TS3
D4/TS2
D3/TS1
1
1
D2/TSO
D1
D0
-
-
-
-
-