Data Sheet
www.waveshare.com
38/40
pattern
is 30 minutes. After 30 minutes, it needs 30min to let
temperature rise to -25℃ . One temperature cycle
(2hrs) is complete.
2. Temperature cycle repeats 70 times.
3. When 70 cycles finished, the samples will be taken out
from experiment chamber and set aside a few minutes.
As EPDs return to room temperature, tests will
observe the appearance, and test electrical and optical
performance based on standard # IEC 60068-2-14NB.
standards.
8
UV exposure
Resistance
765 W/m
2
for 168
hrs,40℃
Standard # IEC 60068-2-5 Sa
9
Electrostatic
discharge
Machine model:
+/-250V, 0
Ω,200pF
Standard # IEC 61000-4-2
10
Package
Vibration
1.04G,Frequency :
10~500Hz
Direction : X,Y,Z
Duration:1hours
in each direction
Full packed for shipment
11
Package Drop
Impact
Drop from height
of 122 cm on
Concrete surface
Drop sequence:1
corner, 3edges,
6face
One drop for
each.
Full packed for shipment
Actual EMC level to be measured on customer application.
Note: (1) The protective film must be removed before temperature test.
(2) There’s temperature vs display quality limitation in our display module, we guarantee 1 pixel display quality from
5℃ ~ 30℃, and 2 pixel display quality for 0℃~ 5℃ & 30℃ ~ 40℃.
(3) In order to make sure the display module can provide the best display quality, the update should be made after putting the display
module in stable temperature environment for 15 mins.