10. Reliability Test
Test Condition Method
1
High-Temperature
Operation
T = +50°C, RH = 30% for 240 hrs IEC 60 068-2-2Bp
2 Low-Temperature Operation
T = 0°C for 240 hrs IEC 60 068-2-2Ab
3 High-Temperature Storage
T = +70°C, RH=23% for 240 hrs
(Test In White Pattern)
IEC 60 068-2-2Bp
4 Low-Temperature Storage
T = -25°C for 240 hrs
(Test In White Pattern)
IEC 60 068-2-1Ab
5
High-Temperature,
High-Humidity Operation
T = +40°C, RH = 90% for 168 hrs IEC 60 068-2-3CA
6
High Temperature,
High- Humidity Storage
T = +60
℃
, RH=80% for 240hrs
(Test In White Pattern)
IEC 60 068-2-3CA
7 Temperature Cycle
-25℃ +70℃, 100 Cycles
30mins 30 mins
(Test In White Pattern)
IEC 60 068-2-14
8 Solar Radiation Test
765 W/m
2
for 168hrs,40
℃
(Test In White Pattern)
IEC60 068-2-5Sa
9 Package Vibration
1.04G, Frequency: 10~500Hz
Direction: X,Y,Z
Duration: 1 hours in each direction
Full packed for shipment
10 Package Drop Impact
Drop from height of 122 cm on concrete
surface.
Drop sequence: 1 corner, 3 edges, 6 faces
One drop for each.
full packed for shipment
11
Electrostatic Effect
(non-operating)
(Machine model)+/- 250V
0Ω, 200pF
IEC 62179, IEC 62180
12 Stylus Tapping
POLYACETAL Pen: Top R:0.8 mm
Load: 300gf
Speed: 2 times/sec
Total 13,500times,
Test with bezel and
device to simulate full
product test
Actual EMC level to be measured on customer application.
Note:The protective film must be removed before temperature test.
[Criteria]
In the standard conditions, there is not display function NG issue occurred (Including: line defect, no image).
All the cosmetic specification is judged before the reliability stress.