Datasheet

14
10. Reliability Test
Test Condition Method
1
High-Temperature
Operation
T = +50°C, RH = 30% for 240 hrs IEC 60 068-2-2Bp
2 Low-Temperature Operation
T = 0°C for 240 hrs IEC 60 068-2-2Ab
3 High-Temperature Storage
T = +70°C, RH=23% for 240 hrs
(Test In White Pattern)
IEC 60 068-2-2Bp
4 Low-Temperature Storage
T = -25°C for 240 hrs
(Test In White Pattern)
IEC 60 068-2-1Ab
5
High-Temperature,
High-Humidity Operation
T = +40°C, RH = 90% for 168 hrs IEC 60 068-2-3CA
6
High Temperature,
High- Humidity Storage
T = +60
, RH=80% for 240hrs
(Test In White Pattern)
IEC 60 068-2-3CA
7 Temperature Cycle
-25 +70, 100 Cycles
30mins 30 mins
(Test In White Pattern)
IEC 60 068-2-14
8 Solar Radiation Test
765 W/m
2
for 168hrs,40
(Test In White Pattern)
IEC60 068-2-5Sa
9 Package Vibration
1.04G, Frequency: 10~500Hz
Direction: X,Y,Z
Duration: 1 hours in each direction
Full packed for shipment
10 Package Drop Impact
Drop from height of 122 cm on concrete
surface.
Drop sequence: 1 corner, 3 edges, 6 faces
One drop for each.
full packed for shipment
11
Electrostatic Effect
(non-operating)
(Machine model)+/- 250V
0Ω, 200pF
IEC 62179, IEC 62180
12 Stylus Tapping
POLYACETAL Pen: Top R:0.8 mm
Load: 300gf
Speed: 2 times/sec
Total 13,500times,
Test with bezel and
device to simulate full
product test
Actual EMC level to be measured on customer application.
NoteThe protective film must be removed before temperature test.
[Criteria]
In the standard conditions, there is not display function NG issue occurred (Including: line defect, no image).
All the cosmetic specification is judged before the reliability stress.