Specifications

User Manual 301/302
Inter-Channel Control
Phase Offset
Range in Degrees 0 to 360°
Range in Waveform Points 0 to waveform length
Range Setting Resolution
Coarse 8 points
Fine 1 point to 128 k points, 8 points above 128 k.
Accuracy ±[Resolution + (3/wave_period) x 360],
(wave_period in ns)
Initial Skew <±2 ns
Inter-Channel Dependency
Separate control Amplitude, offset, standard waveforms, user
waveforms, amplitude modulation
Common Control Sample clock, frequency, trigger modes, user waveform
size, user waveform divider, sequence table, SYNC
output
Auxiliary Outputs (I & Q)
AUX Output
Operation Outputs the same waveform as the Main output.
Connector Front panel BNC
Impedance 50, ±1%
Level 1 V typical into 50
Protection Protected against temporary short to case ground
SYNC Output
Connector Front panel BNC
Stand-by SYNC Off or Normal
Impedance 50, ±1%
Level >2 V into 50, 4V nominal into 10K
Protection Protected against temporary short to case ground
Validators BIT, LCOM, PULSE
Position Point 0 to n, programmable
Width Control From 1% to 99%, programmable when placed in Pulse
validator mode
Specifications
vi