Installation guide
SmartSensor 105 User Guide – Wavetronix LLC 9/20/07  - - 
13
The Click! 200 has 12 screw terminal connections on both the top and the bottom (see 
Figure 7). The screw terminals on the top of the module are surge protected: 
Back  The back four terminals consist of one +DC power, -DC and two surge 
ground connections; 
Middle  The middle four terminals are for RS-485 communication and consist of a 
+485 connection, a -485 connection and two connections for ground. One of 
the ground connections is used as ground for RS-232 communication; 
Front  The front four terminals are for RS-232 communication and consist of TD, 
RD, CTS and RTS. 
Figure 7 – Surge Protected Terminal Connections 
Figure 7 above shows the PROTECTED side of the Click! 200. The UNPROTECTED 
side of the Click! 200 contains the same screw terminal connections, but in the opposite 
order. 