User's Manual
18
CHAPTER 1 o INSTALLING THE SMARTSENSOR 105
Applying Silicon Dielectric Compound
Use the following steps to correctly apply the silicon dielectric compound:
Tear the tab o the tube of silicon dielectric compound.1
Squeeze about 25% of the silicon into the connector at the base of the 2
SmartSensor as shown in Figure 1.5. Be sure to wipe o any excess
compound.
Applying Silicon Dielectric CompoundFigure 1.5 –
Connecting the SmartSensor Cable
Aach the cable connector to the 25-pin connector at the base of the 1
SmartSensor as shown in Figure 1.6. The SmartSensor connector is keyed
to ensure proper connection; simply twist the connector clockwise until
you hear it click into place.
Strap the cable to the pole or run it through a conduit to avoid undue 2
movement from wind and reduce cable strain.
Attached CableFigure 1.6 –