CHAPTER 2 o CONNECTING POWER AND SURGE PROTECTION
20
Smart
Sensor
Underground
Cable
Protecting the SensorFigure 2.1 –
Note
If you choose not to use surge protection in your installation, please contact
Wavetronix Technical Services for assistance.
In many installations, the pole-mount cabinet is also connected to a main trac
cabinet via an underground homerun cable. To protect the trac cabinet, a
second surge device is strongly recommended. Follow the steps below to include
surge protection using Click! 200 devices (see Figure 2.2):
Install one Click! 200 device in a pole-mount box on the same pole as the 1
sensor being protected.
Install another Click! 200 in the main trac cabinet. 2
Connect the SmartSensor cable from the sensor to the PROTECTED side of 3
the Click! 200 in the pole-mount cabinet. The SmartSensor cable should be
kept as short as possible.
Connect a SmartSensor cable from the UNPROTECTED side of the Click! 4
200 on the pole to the UNPROTECTED side of the Click! 200 in the main
trac cabinet.