User's Manual
76
CHAPTer 7 o DATA COLLECTION
Data Collection SetupFigure 7.1 –
Step 1: Congure Data Storage
The Interval (Bin) Size option species the interval of time over which trac
variables like volume, speed, occupancy and classication are aggregated. This
type of data is called interval data. The minimum interval allowed is ve seconds.
By default, the checkbox next to Memory Overwrite is checked. This means that
your study will run indenitely and repeatedly overwrite the ash memory
onboard storage. This means that in order to not lose collected data, you must
download it to a log on your computer before it is overwrien.
Alternatively, you can uncheck the Memory Overwrite checkbox. In this case,
the study will run only until the sensor’s ash memory has been lled with
interval data.
Note
Once the ash memory buer is full, it must be erased before it can be
reused. Before you erase the stored data, you will want to download the
data to a log le on your computer.
The third line under Step 1 displays the Flash Storage Time. This shows the
duration of interval data that a full ash buer holds, calculated for you as
a number of days and hours. Because of the way ash memory is managed,
the Flash Storage Time will vary based on whether or not you have Memory
Overwrite enabled.