User's Manual

78
CHAPTer 7 o DATA COLLECTION
Note
This screen can be accessed via the Data Collection Download screen by
clicking on the View Data Buer Status buon.
The sensor’s SRAM buer contains up to 246 of the most recent interval data
records. This type of storage is temporary because SRAM is volatileits contents
will be lost if the sensors power supply is interrupted. The sensors ash
memory buer contains up to 2975 interval data records. This type of storage is
permament because ash memory is nonvolatileit will retain its contents even
if the sensor’s power supply is interrupted.
Note
The smallest amount of ash memory that can be erased at one time
represents several interval data records. As a result, if you are collecting
data with the Memory Ovewrite feature enabled, you will not typically see
the buer ll up 100%. In fact, you may see the usage fall from near 100% to
something near 80%. This is because as usage approaches 100%, a portion
of the oldest contents are erased in order to make room for newer data.
If you want to force the contents of the sensors SRAM buer to be wrien to
ash memory, click the Transfer>> buon.
Data Download
To download interval data stored on the sensor in the SRAM and ash memory
buerssuch as data collected in a studygo to Data Collection>Download.
The screen that comes up is divided into two sections, Download Interval Data
and Interval Data Buers (see Figure 7.3).