User's Manual

64
Response Delay This is used to configure how long the sensor will wait
before responding to a message received. This is useful for some
communications devices that are unable to quickly change transmission
direction. The default value is 10 milliseconds. This value can be selected
for both of the sensors ports independently.
Data Push Data can be pushed over port 1, port 2, or both. To prevent
data push, select “None”. In many cases, data push will only occur over Port
2 which is typically designated for detection calls (based upon the pre-wired
connections of a PCU).
Source In normal use the source is always the radar Antenna. However in
some cases, other sources may be used for demonstrations or evaluations.
When the source is switched to diagnostic, the antenna is not longer used.
Instead a predetermined sequence of traffic will appear. The replay source
is only available if the sensor is equipped with this special hardware.
Note
If for some reason SSMMX connects over the Port that SmartSensor Matrix is
pushing data, the software will continue to poll the sensor for detection call
messages. This will help keep the intersection operating as normal during the
configuration process.
Note
A green arrow is used to show the port over which SSMMX is connected to the
sensor. In many cases, the SSMMX will be connected over Port 1. Port 1 is
usually designated for command and control and is connected to the blue RS-
485 wire pair. However, during troubleshooting or other special cases SSMMX
may connect to the sensor over Port 2. Port 2 is connected to the orange RS-
485 wire pair and is typically used for detection calls.