User's Manual
Table Of Contents
89
Likewise, the next three baud rate switches (4-6) for S5 are used to select the baud
rate for Bus 2. If these baud rate switches are all off then the Bus 2 baud rate is
software configurable. Otherwise, the pattern of these switches selects the Bus 2
baud rate.
S5 DIP
Switch Pattern
Bus 1
Baud Rate
S5 DIP
Switch Pattern
Bus 2
Baud Rate
1 2 3
Software
configured
4 5 6
Software
configured
1 2
3
9600 bps
4 5
6
9600 bps
1
2
3
19200 bps
4
5
6
19200 bps
1
2 3
38400 bps
4
5 6
38400 bps
1
2 3
57600 bps
4
5 6
57600 bps
1
2
3
115200 bps
4
5
6
115200 bps
Figure D.4 – Baud Rate Selection using Baud Rate Switches
There are two methods of software-driven configuration: mode switch (on the card’s
front panel) and Click! Supervisor software.
Figure D.1 lists the modes that can be selected using the front panel mode switch.
To select a mode hold down the mode switch button, until the corresponding LED
activates. Release the button and then momentarily press it once again in order to
select the mode.
Menu Mode LEDs
Description
Red Normal operation
Blue Flashing
Select input channel group
Green
Automatically configure baud rates to a compatible
device