User's Manual

APPENDIX 107
backwards (reverse polarity), the device is not powered or the surge protection circuitry is
no longer operational. If the LED ickers on an then o when power is applied, this means
that the device is conducting power, but the surge is no longer fully functional. When the
surge is no longer fully functional, please contact Wavetronix Technical Services for as-
sistance.
Appendix D – Click 600 Installation
e Click 600 cabinet interface device is a single, compact module that performs all the
functions of the preassembled backplates: power conversion, surge protection, and sending
detection data to the appropriate contact closure devices.
Figure D.1 – Click 600
e Click 600 is a shelf-mount device, meaning its meant to be set on a shelf in the traf-
c cabinet. However, if you’d prefer to ax it to the wall of a NEMA-style trac cabinet,
attach the included U-channel mounting brackets to the device and use them to mount it
on the cabinet wall.
Connecting AC Power
Included with the Click 600 is an AC power cord. Connect it from your AC power source
to the IEC connector on the back of the device. e Click 600 will take that AC power
and convert it to DC, then send that power to any connected sensors (which run on 10–28
VDC).
Warning
Make sure power to AC mains is disconnected while wiring the AC input.
Next to the IEC connector is a switch that turns power on and o for the whole device.