User's Manual

Installation Guide 19
Warning
: Transient or electrostatic discharges that may occur at the WBS-
2400/5800, for example a lightning strike, may damage your network
equipment connected to the WBS-2400/5800 and cause personnel injury
or death of persons touching the exposed metal connectors of the
equipment. You must install a properly grounded lightning surge
protector. Carefully follow the installation instructions provided by the
manufacturer of the protection device. See
To ground the Wavion WBS-2400/5800:
The Grounding screw is located on the side panel of the outdoor unit.
To connect the grounding cable:
1. Connect one end of a grounding cable to the grounding terminal and tighten the
grounding screw firmly.
Do the following steps:
a. Remove the nut and star washers from the grounding screw.
b. Attach one star washer to the grounding screw.
c. Attach #10 AWG bare copper wires with an M6 terminal ring to the
grounding screw.
d. Attach the second star washer and tighten the nut.
2. Connect the other end of the grounding cable to a good ground (earth)
connection. (For example, a grounding rod).
Figure 4.7 Grounding
Grounding the Data Protection Device
The grounding method for an indoor data protection device is shown in
Figure 4.8
.
To ground an indoor data protection device: