User's Manual

18 Wavion Networks
To ground the Wavion WBS-2400/5800:
The Grounding screw is located on the side panel of the outdoor unit.
To connect the grounding cable:
1. Connect one end of a grounding cable to the grounding terminal and tighten the
grounding screw firmly.
Do the following steps:
a. Remove the nut and star washers from the grounding screw.
b. Attach one star washer to the grounding screw.
c. Attach #10 AWG bare copper wires with an M6 terminal ring to the
grounding screw.
d. Attach the second star washer and tighten the nut.
2. Connect the other end of the grounding cable to a good ground (earth)
connection. (For example, a grounding rod).
Figure 4.5 Grounding
Grounding the Data Protection Device
The grounding method for an indoor data protection device is shown in
Figure 4.6
.
To ground an indoor data protection device:
1. Position the protection device as close to the building entrance as possible.
2. Attach a length of #10 AWG bare copper wires to the ground post on the data
protection device.
3. Attach the other end of the grounding wire to the ground connection of an
electrical outlet or a grounded water pipe.