User's Manual

Installation Guide 21
When connecting to the Ethernet port, if you need to terminate the Ethernet cable, use a
standard RJ45 termination. Use a shielded RJ45 plug and be sure to connect the shield of
the Ethernet cable to the shield of the RJ 45 plug.
To connect to the data port:
1. Make sure that the power is turned off for the designated circuits.
2. Run shielded Category 5 Ethernet cable appropriates for outdoor use from a POE
injector to the Wavion WBS-2400/5800 through the lightning protection device.
See "Grounding the Data protection device" section for connection diagram.
3. Connect one end of the Category 5 cable to the "RADIO" port of the Wavion POE
injector.
4. Connect the other cable end to ETH port on the WBS-2400/5800. Use a shielded
RJ45 8-pin modular plug to terminate the cables at the desired lengths.
5. Place the sealing rubber on the cable and push it towards RJ45 connector on
WBS-2400/5800
6. This port must be sealed with the provided rubber seal, make sure that the
waterproof Seal strip is also attached.
W
ARNING: The shields of the Cat5 cable must be properly terminated and
bonded to the unit and to the protective earth (PE) at the building
entrance. This provides protection against the risk of fire, electrical hazard
and ensures the reliable operation of this equipment.
Note:
National Electrical Codes (NEC) Article 800 requires the use of
an Agency Listed (UL/CSA) Building Entrance Protector for all power
and communications cables entering a building. Article 800 is intended
to protect the building and occupants from fires caused by transient
voltage and current surges.
Note:
This is not a mid-span powered device. Do not attempt to daisy-
chain Power Over Ethernet devices.