Connecting Power and DATA
The following describes how to apply power and data to the WBS-2400/5800X
Caution: You must always install an external grounding wire. Perform a
simple continuity check between the WBS-2400/5800and the ground
termination point to confirm. You must also ground the outdoor data
protection device to a ground rod or a bonded pipe. Make sure you have
completed grounding before you connect power to the WBS-2400/5800X.
The Wavion WBS-2400/5800 is equipped with two RJ45 connectors. The right hand port
named "TEST" is for engineering use only (!) and has to be sealed with the sealing
rubber. Use the ETH port to connect data and power cable.
Figure 4.11 Connecting PoE cable
WARNING: The port named "TEST" is for engineering use only. In any
case do not connect PoE source to "TEST" port (!)
WARNING: The shields of the Cat5 cable must be properly terminated and
bonded to the unit and to the protective earth (PE) at the building
entrance. This provides protection against the risk of fire, electrical hazard
and ensures the reliable operation of this equipment.