WELL SYSTEM AUTOMATIC CONTROL VALVE PROGRAMMING
Clock MUST be set to 12:01 PM to get into
programming mode.
Step 1: Press and hold one of the up or down arrows until the clock
moves. Set the time to 12:01 PM. Push the Recycle button to set.
(recycle button)
Step 2: Press and hold the up and down buttons at the same time
to get into the Master Programming Mode. A pencil icon lets you know
you are in programming mode.
The code in the upper left shows the portion of the program being changed.
The up and down buttons change the value on the right.
Step 3: Screen upper
left reads DF. Set to GAL.
Step 4: Push Recycle.
Set VT to dF 1b.
Step 5: Push Recycle.
Set CT to tc.
Step 6: Push Recycle.
Set NT to ---1.
Step 7: Push Recycle.
Set DO to 1
Days between backwash
cycles can be adjusted
based on iron/sulfur levels
Step 8: Push Recycle.
Set RT to 2:00am
Step 9: Push Recycle.
Set BW to 14
Step 10: Push Recycle.
Set BD to 40
Step 11: Push Recycle.
Set RR to 10
Step 12: Push Recycle.
Set BF to OFF
Step 13: Wait for time
to display…
Step 14: Press and
hold up or down arrow,
this gets time moving. Set
TD to correct time.
Push Recycle to
complete the setup.