User Manual

2
To set the custom temperatures, simply power up the thermostat to be added to the
network and set the modes at the desired temperatures. This must be done before adding
the thermostat to the Room Key Controller. The Room Key Controller will grab the
temperature set points from the thermostat when it is added to the network. Multiple
thermostats are supported but only the temperatures from the first thermostat will be
recorded. The Room Key Controller will always set all thermostats in the room to the
same temperature.
This mode of operation is particularly useful when hotel guests manually change the
thermostat temperature. Once the card is inserted or removed, all thresholds will go back
to the originally programmed setting.
Custom Set Points Re-Programming
To set new custom set points for the Room Key Controller follow the following
procedure:
1. Power down all thermostats in the room.
2. Insert the key card in the slot. Wait 15 seconds.
3. Remove key card from the slot. Wait 15 seconds.
4. Power up all thermostats in the room and set all of the thresholds manually in the
thermostats.
5. Insert the key card in the slot. –Room Key Controller will grab the new thresholds
and program them into non volatile memory.
Stand Alone \ Indicator Mode
The Room Key Controller can be configured to act in Stand Alone mode (factory default)
where all control functions for the room are controlled by the Room Key Controller or in
Indicator mode where the Controller switches from Room Controller to Key
insertion\removal sensor. In this mode, the Room Key Controller sends key status
information to another controller such as Hotel Manager AG. When the Room Key
Controller is reset, it will automatically go to Stand Alone mode. Indicator mode can be
set via the parameter command which is only accessible with a compatible Controller.
PARAMETER #
PARAMETER
NAME DEFAULT
DESCRIPTION
VALID
VALUES
1 Stand Alone 1 Sets Stand Alone mode (1)
or Indicator mode (0)
0-1