Automatic Garage Door Opener OWNER INSTALLATION AND USER MANUAL
24 
Step 26: Connecting Door Arm to Door 
Door Mounted Bracket 
Visually align cushion arm connecting hole with middle 
hole of door bracket by rotating tube section in appropriate 
direction. 
Release trolley (cushion arm attached) with manual 
release cord and pull trolley a few inches toward motor. 
Now rotate cushion arm tube section 2 turns 
counterclockwise to provide a cushion when door is closed 
or encounters an obstruction. Align connecting hole in 
cushion arm to middle hole in door 
bracket; insert 3/8” dia. bolt and 
tighten locking nut, allowing for free 
pivoting of arm. 
Note: Do not over tighten locking 
nut, as this will cause binding 
between cushion arm and door 
bracket. 
WARNING: Failure to secure door 
arm to door bracket with locking nut can cause door arm to become disengaged from 
the trolley and fall, resulting in possible damage or personal injury. 
Step 27: Setting Door Close Travel Plus “Contact Obstruction Sensing” Test 
With wall control up/down button, activate door to 
full open position; reactivate to close position. The 
door should stop on the floor with the cushion arm 
and the bottom door seal slightly compressed. If the 
door reverses off the floor, turn close travel knob 1/4 
turn “less”. If door is not completely closed, turn 
travel knob 1/4 turn “more”. Repeat if necessary. 
IMPORTANT! Test “Contact Obstruction Sensing Feature” 
IMPORTANT: After installing opener, the door must reverse when it contacts a 1 inch high object on the floor. 
Activate the door to the full, open 
position and place a 1” (25mm) solid 
test obstacle on the floor under the 
garage door. Activate the door to the 
closed position. The door should 
reverse upon contact with the 1” 
obstacle. 
If door stops on the 1” obstacle, adjust 
the close travel knob 1/4 turn “more” 
until door reverses upon contact with 
obstacle. Repeat if necessary. 
When the door reverses, remove the test object and run the full cycle of open and close of the door. Door should not 
reverse when it comes to the fully closed position. 
Note: If opener fails to pass this test, repeat Step 27. Also see Adjustment #2, page 28, (Contact Obstruction 