Owner`s manual
16 of 46
Copyright 2015 by Southern Pride Distributing, LLC Volume 1
GAS CONNECTION INSTRUCTIONS
For smokers equipped with casters, the installation shall be made with a connector that complies with the
Standard for Connectors for Movable Gas Appliances, ANSI Z21.69 CSA 6.16, and a quick-disconnect device
that complies with the Standard for Quick-Disconnect Devices for Use With Gas Fuel, ANSI Z21.41 CSA 6.9.
Adequate means must be provided to limit the movement of the appliance without depending on the connector
and the quick-disconnect device or its associated piping to limit the appliance movement.
The restraining device may be attached to the leg gusset of the leg nearest the gas connection.
WARNING: Operator should be aware that a restraint device is in place on smokers equipped with
casters. If disconnection of the restraint is necessary, it must be reconnected after the appliance has been
returned to its originally installed position.
IMPORTANT ITEMS TO CHECK BEFORE FIRING THE BURNER
1. Gas line MUST be installed by a qualified technician and in accordance with this Manual.
2. Gas line MUST include an easily accessible manual shutoff valve, drip leg, and pressure gauge port.
3. Gas pipe size MUST be in accordance with the Pipe Capacity Chart in this Manual (pages 14 and 15).
4. Gas line MUST be tested for leaks under pressure.
5. Gas line MUST be purged to remove any air in the system.
6. Gas line pressure MUST be checked and MUST NOT exceed the maximum pressure specified in the
Burner Specifications on page 17.
7. Burner orifice MUST correlate with the type of gas being supplied, as specified in the Burner Specifica-
tions on page 17.
WARNING:
Improper gas hookup will void the warranty and could result in a hazardous condition.