Installation Sheet
If you have any questions regarding the service or
repair of this machine, call or write to:
WAYNE Pumps
Attn. Technical Services Department
101 Production Drive
Harrison, Ohio 45030
Tel: 1-800-237-0987
TROUBLESHOOTING CHART
Symptom Possible Cause(s) Corrective Action
Pump will not
start or run
1. Blown fuse or breaker
2. Low line voltage
3. Worn motor
4. Impeller not rotating
5. Thermal Protector open
1. If blown, replace with the proper sized fuse or reset the breaker.
2. If voltage is under 108 volts, check wiring size.
3. Replace pump.
4. If impeller will not turn, disconnect pump from power source,
remove volute cover and remove blockage.
5 a. Water temperature is too high, move to cooler water.
b. Inlet clogged, remove debris.
c. Motor seized, replace pump.
Pump starts but
delivers little or
no flow
1. Inlet screen clogged
2. Low line voltage
3. Restriction in discharge hose
4. Discharge lift too high
1. Clean debris from screen.
2. If voltage is under 108 volts, check wiring size.
3. Unwind garden hose, remove any kinks or restrictions in hose.
4. Water level to end of garden hose is 25 ft. or greater.
6
4
www.waynepumps.com