User's Manual

17
INSTRUCTION MANUAL
7.2.2 Binding a Dual 2.4 Dual FHSS micro series receiver to the transmitter module
You can bind as many receivers as are required to each transmitter module/transmitter as each transmitter module transmits an individual code, of
which there are millions, to the receiver which must store the code before it will become ‘live’. This makes it impossible for more than one weatronic
receiver to react to a weatronic transmitter module at the same time.
Before a weatronic transmitter module and a weatronic Dual 2.4 Dual FHSS series receiver can communicate with each other they must be bonded
together (Quick Binding). During this binding process the receiver will receive and store the code transmitted by the transmitter module and the
transmitter module will receive and store the receiver’s serial number. Once this process is complete, the receiver will only react to signals transmitted
by that transmitter module. The process for binding a receiver to a transmitter module is very simple and should be carried out as follows:
During this process, you must ensure that the transmitter module and the receiver are a minimum of half a metre (50 cms)
apart.
Two buttons are fitted to the transmitter module, labelled Button 1 and Button 2”. These buttons become active a few seconds after switching
on the transmitter and this will be signalled by all 3 LEDs flashing. Once the transmitter is switched on and the module has conducted it’s self-test
the red LED will flash as the module is not receiving a return signal and the green LED will omit a short double flash indicating that it is not bonded.
The transmitter module is now ready for bonding. Begin the bonding process by pressing Button 2 for at least 5 seconds, at which point the green
LED will begin to flash rhythmically.
The Dual 2.4 Dual FHSS micro receiver should now be switched on or power connected. Once the receiver is switched on the red jumper should be
fitted to the pins on the side of the receiver opposite the servo sockets. The jumper can be fitted either to the upper and middle or to the lower and
middle pins and binding will begin after approximately 5 seconds.
Once the transmitter module and the receiver are bonded together the green STATUSLED will illuminate solidly on both components. The red
jumper may now be removed from the receiver.
Weatronic transmitter module showing the earphone socket on the left, the USB cable socket and the SD Micro card slot
7.2.3 Quick Binding
As the serial number of each Dual 2.4 Dual FHSS micro receiver which has been bonded to it is stored within the module’s memory, re-bonding (quick
Binding) a receiver is extremely quick and easy. Simply switch on the transmitter followed by the receiver and once the self test is complete press
“Button 2” once briefly, finished! When the Quick Binding process is complete the green “STATUS” LEDs on both the transmitter module and the
receiver will flash at regular intervals (twice per second). / will illuminate solidly.
7.2.4 Failsafe settings for the Dual 2.4 Dual FHSS micro series receiver
The Fail Safe function of a Dual 2.4 Dual FHSS micro receiver is activated and set using the transmitter and all channels can be given a Fail Safe
position. To set the Fail Safe positions the red jumper must be fitted to the lower (red, black) pins on the receiver before the receiver is switched on.