Air Conditioner User Manual

Connection of 2 Pipes with Hose
The proper connection of fuel lines with hoses is shown
in Fig. 805.
Fig. 805 Pipe/Hose Connection
8.6.3 Dosing Pump
The dosing pump is a combined delivery, dosing, and
shut-off system and is subject to certain installation crite-
ria (see Figs. 801 and 806).
AT 2000 S. 12 Volt and 24 Volt - Gasoline and Diesel
AT 2000 S D. 12 Volt and 24 Volt - Diesel DP 30
Installation Position only Horizontal
Fig. 806 Dosing Pump, Installation Position
and Attachment
8.6.3.1 Installation Location
It is advantageous to mount the dosing pump in a cool
location. The ambient temperature must never exceed
+20 °C during operation.
Dosing pump and fuel lines must not be installed in loca-
tions exposed to heat radiated by hot vehicle compo-
nents. A heat shield is to be provided as required.
8.6.3.2 Installation and Attachment
The dosing pump is to be attached with anti-vibration
mounts. The installation location is limited according to
Fig. 806 to ensure sufficient self-venting capability. Due
to the danger of corrosion the plug connection between
dosing pump and dosing pump cable loom may only use
Webasto original parts.
8.6.4 Fuel Filter
Fig. 807 Fuel Filter
804
0-90°
0-90°
A
ø 5
0 - 90°
8 Servicing
Air Top 2000 S
Clamp
Bubble
Bubble
Wrong
Correct
Only a Webasto filter, P/N 50487171A, is allowed to be
used if the fuel is expected to be contaminated. Install
vertically if possible, however at most horizontally (check
flow direction).