Installation manual

www.webasto.us 5 Webasto Product N.A., Inc.
Air Top 2000 S Regulation for Installation in the Vehicle
2.6 Hot Air Inlet
2.6.1 The supply of heating air must consist of either fresh air or recirculated air and must be taken from a clean area
which cannot be contaminated by exhaust fumes from the engine, the internal combustion heater or any
other source in the vehicle.
2.6.2 The inlet line must be protected by a grating or other suitable means.
2.7 Hot Air Outlet
2.7.1 Hot air lines within the vehicle must be positioned or protected in such a way as to exclude all risk of injury or
damage caused by direct contact.
2.7.2 The air outlet must be positioned or protected so that it cannot be obstructed by other objects.
2.8 Automatic Control of the Heating System
When the engine stops, the heating system must cut out automatically and the fuel supply must be stopped within 5
seconds.
The heating system may remain in operation if a manual unit has already been activated.
NOTE: Failure to follow the installation instructions and the notes contained therein will lead to all
liability being refused by Webasto. The same applies if repairs are carried out incorrectly or with
the use of parts other than genuine Webasto service parts. This will result in the invalidation of the
type approval for the heater and therefore of its homologation / type licence.