Technical data
Air Top 2000 S Technical data
75
Heater Operation Air Top 2000 S-B Air Top 2000 S-D
EC licensing symbol e1*72/245*95/54*1085*--
e1*2001/56*0014*--
Model Air heater with evaporator burner
Heat output Control
range
1.1 - 2.0 kW 0.9 - 2.0 kW
Fuel Petrol Diesel
Fuel consumption Control
range
0.1 .. 0.2 kg/h (0.16 .. 0.27 l/h) 0.1 .. 0.21 kg/h (0.12 .. 0.24 l/h)
Rated voltage 12V 12 / 24V
Operating voltage range 10 - 15V 10 - 15 /20 - 30V
Rated power consumption Control
range
9 -22 W
Max. ambient temperature:
Heater - Operation
- Storage
Metering pump - Operation
- Storage
Control element - Operation
- Storage
-40... +40°C
-40... +85°C
-40... +20°C
-40... +85°C
-40... +75°C
-40... +85°C
Maximum combustion air inlet temperature -40... +20°C
Adjustment range for interior temperature Control
range
+10... +45°C
Delivery rate of the hot air against 0.5 mbar Max. 70 m
3
/h
CO
2
in the exhaust fumes (normal function range) Max. 9.5 ... 10.5 9.5 ... 12.0
Heater dimensions Length 311 ± 2 mm
Width 120 ± 1 mm
Height 121 ± 1 mm
Weight 2.6 kg