Air Top 2000 ST Fuel supply
55
7.5.2. Installation and attachment
The metering pump must be secured with a vibration-damping mounting
(for example a rubberised clip). Its installation position is limited as shown
in Figures 14 and 15 in order to ensure effective automatic bleeding.
As a result of the risk of corrosion, only genuine Webasto parts may be
used for the plug connections between the metering pump and the meter-
ing pump wiring harness.
7.6. Fuel filter
Only a Webasto filter, order no. 487 171, is allowed to be used if the fuel
is expected to be contaminated. Install vertically if possible, however at
least horizontally (check flow direction).
Fig. 16: Fuel filter
0° - 90°
AT2000ST_Installation_Instructions.book Page 55 Wednesday, May 29, 2013 12:54 PM