Technical data
Fault lock-out Air Top 2000 ST
72
15.1. Error code output
NOTE:
The error code is output if the heater is fitted with a control element after
an error has occurred by the switch-on indicator/error code indicator flash-
ing. After 5 seconds of fast flashing, the error code will be output by a se-
quence of long flash pulses, the number of flashes is shown in the table
below.
If the heater is fitted with a combination timer, an error message will ap-
pear on the display of the timer after a fault occurs: If the control element
is used the error number is indicated by the indicator light flashing:
F 00 Control unit error / incorrect data set / customer bus defective
F 01 No start (no flame formation)
F 02 Flame failure (repeated >3)
F 03 Undervoltage or overvoltage
F 04 Premature flame recognition
F 05 Flame monitor (petrol heater) interrupt or short circuit
F 06 Temperature sensor interrupt or short-circuit
F 07 Metering pump interrupt or short circuit
F 08 Fan motor interrupt or short circuit overload or blocked
F 09 Glow plug interrupt or short circuit
F 10 Overheating
F 11 Overheating sensor interrupt or short circuit
F 12 Heater lock-out
F 14 Overheating sensor incorrect position
F 15 Setpoint generator interrupt