Technical data

Heater Operation Air Top 2000 ST B Air Top 2000 ST D
Type test permit EMC
heater
E1 10R- 04 1085
E1 122R- 00 0216
Model Air heater with evaporator burner
Heat output Control range 1.0 - 2.0 kW 0.9 - 2.0 kW
Fuel Petrol
EN 228
DIN 51625
Diesel/PME
EN 590
DIN 51603
DIN EN 14214
Fuel consumption Control range 0.1 - 0.2 kg/h (0.14 - 0.27 l/h) 0.1 - 0.21 kg/h (0.12 - 0.24 l/h)
Rated voltage 12 V 12/24 V
Operating voltage range 10.5 - 16 V 10.5 - 16 / 20.5 - 31 V
Rated power consumption Control range 14 - 29 W
Max. ambient temperature:
Heater: - Operation
- Storage
Metering pump: - Operation
- Storage
Control Panel: - Operation
- Storage
-40 to + 40 °C
-40 to + 85 °C
-40to+2C
-40to+8C
-40to+7C
-40to+8C
Maximum combustion air inlet temperature -40 to + 20 °C
Adjustment range for interior temperature Control range +5 to + 35 °C
Delivery rate for hot air
at fan speed
against
0.5 mbar
max. 93 m
3
/h
at 4750 rpm
CO
2
in exhaust gas (permitted function range) 1 kW
2kW
5.0 - 8.0 %
9.0 - 12.5 %
5.0 ... 8.0 %
9.0 ... 12.5 %
Heater dimensions Length 311 r 2mm
Width 120 r 1mm
Height 121 r 1mm
Weight 2.6 kg
Technical data Air Top 2000 ST
74
AT2000ST_Installation_Instructions.book Page 74 Wednesday, May 29, 2013 12:54 PM