Service manual

Webasto Diesel Cooker X 100 5 Updating and repair
501
WARNING
The cooker must not be operated in enclosed areas
such as garages and workshops without an
emissions extraction system.
5.1 Updating
There may be a maximum of 32 parameter files
programmed on the control unit.
The parameters may be put on the control unit either
one at a time or all together.
XPS software
Download the programme onto your computer; the
name of the programme is xplink.exe. Hook a data-
transmission cable between the computer and
control unit. The length of the cable is 1.5 m and you
hook it to the serial port. If your computer does not
have a serial port, then the data-transmission cable
must be connected via an USB adapter.
For choosing the device
For choosing the PC’s port
From the control unit to the PC
From the PC to the control unit
Checking this box enables you to
choose all devices at one time
Amount of operating hours
Signifies what programme
version is being used on
the control unit
Parameter files may be saved
from the file or manually edited
Figure 1
17: Device 17
9500
5500
11000
9500
1450
3000
240
Make sure you always use the latest
parameters.
Make sure the USB adapter you
use is compatible with your operat-
ing system.
5 Updating and repair