FEEL COOL FAST MARINE AIR CONDITIONER Installation & Operation Manual 6/2012
Table of Contents INTRODUCTION ................................................................................................................................................. 4 PACKAGED COMPONENTS .............................................................................................................................. 5 OVERVIEW ......................................................................................................................................................... 5 INSTALLATION ......
Operation / Installation Manual – FCF 5000, 9000, 12000, 16000, 24000 Introduction Thank you for your purchase. No matter which of the following features was the reason for your purchase, we are sure it will meet your needs and give many years of efficient and trouble free use.
Operation / Installation Manual – FCF 5000, 9000, 12000, 16000, 24000 Packaged Components ITEM QUANTITY Air Conditioning unit 1 Mounting Bracket 4 Fuses (3.
Operation / Installation Manual – FCF 5000, 9000, 12000, 16000, 24000 Installation Unpacking and Inspection When the equipment is received, all items should be carefully checked according to the packaged components list within this manual to ensure all components have been received. Examine components for shipping damage. If the unit is damaged, the carrier should make the proper notation on the delivery receipt acknowledging the damage.
Operation / Installation Manual – FCF 5000, 9000, 12000, 16000, 24000 Placement of System Selecting a good location for your air conditioner is the most important part of your preparation. Be sure to consider the size of the area you are cooling, the air distribution needs, and the size of the unit you have chosen. Keeping in mind that cool air has a tendency to fall; it is highly recommended that you locate the supply air grille as high as possible in the cabin.
Operation / Installation Manual – FCF 5000, 9000, 12000, 16000, 24000 The unit should be installed as low as possible, BUT NEVER IN THE BILGE Tools required: OR ENGINE ROOM AREAS, ENSURE THAT THE SELECTED LOCATION • Screws drivers IS SEALED FROM DIRECT ACCESS TO BILGE AND/OR ENGINE ROOM • Pliers VAPORS. Installing the unit as low as possible (such as under a V-berth, • Pipe wrench dinette supply • Wire cutters/crimpers air as high as possible, creates an ideal airflow condition.
Operation / Installation Manual – FCF 5000, 9000, 12000, 16000, 24000 Condensate Drains The condensate drain pan is 2” (50mm) deep with four drain locations. During conditions of high humidity, condensate may be produced at a rate of approximately 1/2 gallon per hour (1.9 liters per hour). It is important to route condensate drains downward to a sump pump. It is not recommended to route condensate drains to the bilge.
Operation / Installation Manual – FCF 5000, 9000, 12000, 16000, 24000 Ducting Good airflow is critical for the performance of the entire system. It is highly dependent on the quality of the ducting installation. The ducting should be run as straight, smooth and taut as possible minimizing the number of 90 degree bends (two tight 90° bends can reduce airflow by 25%).
Operation / Installation Manual – FCF 5000, 9000, 12000, 16000, 24000 Summary of the seawater system installation: 1. Install the speed scoop thru-hull inlet as close to the keel and as far below the water line as possible, facing forward. Bed the scoop with a marine sealant designed for underwater use. 2. Install a bronze, full flow seacock on the speed scoop thru-hull inlet. 3. Install a seawater strainer below the level of the pump with access to filter. 4.
Operation / Installation Manual – FCF 5000, 9000, 12000, 16000, 24000 Electrical Connections, Grounding and Bonding Turn off air conditioner power supply circuit breaker before opening electric box. All air conditioner units have a terminal strip mounted inside the electric box. The terminal strip is labeled for proper connections of the electrical supply, ground wires and pump circuits. A wiring diagram is provided in the electrical box and later in this manual.
Operation / Installation Manual – FCF 5000, 9000, 12000, 16000, 24000 Digital Display Installation DO NOT turn the unit off and immediately turn it back on. Wait at least 30 seconds for refrigerant pressures to stabilize. Before mounting the digital display, consider the location. The digital display should never be mounted in direct sunlight or exposed to excessive moisture. NOTE: The display cable must be grounded at the electrical box.
Operation / Installation Manual – FCF 5000, 9000, 12000, 16000, 24000 Installation Checklist (Review Prior To Installation) Seawater cooling system: Speed scoop located as far below the water line and as close to the keel as possible Shut off valve (sea cock) and speed scoop properly sealed and tightened Seawater pump is at least 1’ (305mm) below water line and securely mounted Strainer mounted below pump with access to filter Double/reversed stainless steel hose clamps on all hose connections Thread sealer
Operation / Installation Manual – FCF 5000, 9000, 12000, 16000, 24000 Wiring Diagrams Power 115V ~ 60Hz 115V ~ 60Hz Line In L 115V ~ 60Hz Neutral N Cooling Pump Line In 1 Cooling Pump Neutral 2 Power 208V / 230V ~ 60Hz 208V / 230V ~ 60Hz Line In L 208V / 230V ~ 60Hz Neutral N Cooling Pump Line In 1 Cooling Pump Neutral 2 Fuse = 3.
Operation / Installation Manual – FCF 5000, 9000, 12000, 16000, 24000 Fuse = 3.15 AL 250V Fuse = 3.
Operation / Installation Manual – FCF 5000, 9000, 12000, 16000, 24000 Fuse = 3.
Operation / Installation Manual – FCF 5000, 9000, 12000, 16000, 24000 Operation Digital Display Operation • Don't install the digital display in a location where it can get wet. • Don’t knock, throw or open the digital display. 1. Remote receiver 6. Fan control button 2. Display 7. Temp. Setting button (Increasing) 3. Fan speed display (HIGH-MID-LOW and AUTO speed) 8. Temp. Setting button (Decreasing) 4. Display of mode operation (COOL-DEHUMIDIFY-HEAT and AUTO) 9. ON/OFF button 5.
Operation / Installation Manual – FCF 5000, 9000, 12000, 16000, 24000 Power ON/OFF • Press ON/OFF button to turn the unit display on. Press the ON/OFF button a second time to select mode and start operation. • While the display is active press the ON/OFF button once to turn the unit OFF. Press the ON/OFF button a second time if the display has already entered sleep mode to turn the unit OFF.
Operation / Installation Manual – FCF 5000, 9000, 12000, 16000, 24000 • In “DEHUMIDIFY” mode, the LED next to the icon will illuminate when mode is selected on the digital display. • In DEHUMIDIFY mode, if the indoor temperature is higher than temperature setting, the unit will run in cooling mode and the fan will run on low speed. FAN Mode Operation Procedure • In “FAN” mode, the room temperature will be displayed and the temperature cannot be set.
Operation / Installation Manual – FCF 5000, 9000, 12000, 16000, 24000 Button / Function and Description (Cover Closed) Wakes up Digital Display Page 21
Operation / Installation Manual – FCF 5000, 9000, 12000, 16000, 24000 Button / Function and Description (Cover Open) Liquid Crystal Display. Opening cover while unit is on will not affect unit operation. NOTE: This is a universal remote; the sleep and timer ON/OFF buttons are not used with this application.
Operation / Installation Manual – FCF 5000, 9000, 12000, 16000, 24000 Battery Replacement in Remote Controller Remote controller battery requirements: Two AAA alkaline cells. 1. Slide the cell cover downward to take out the worn cells. Replace the worn cells. (Note to the correct polarity). 2. Close the cell cover. 3. The LCD will show all the functional figures and letter codes after the batteries are installed. Wait approximately 10 seconds for normal use. 4.
Operation / Installation Manual – FCF 5000, 9000, 12000, 16000, 24000 Error Codes When there are faults within the system, an error code will be displayed on the display controller: Power off the unit and contact professional service.
Operation / Installation Manual – FCF 5000, 9000, 12000, 16000, 24000 Troubleshooting FAULT POSSIBLE REASON CORRECTION Will not start Air conditioning circuit breaker is off Turn circuit breaker on at ship's panel, See control operation section in this manual. Display control is not turned on. Check wiring Diagram and correct if necessary. Fuse is broken Replaced with a new fuse. (3.15 AL 250V) Incorrect wiring at terminal strip.
Operation / Installation Manual – FCF 5000, 9000, 12000, 16000, 24000 Continued: FAULT POSSIBLE REASON CORRECTION Low air flow Air flow is blocked Remove any obstructions in return air stream, Clean return air filter and grille. Check for crushed or restricted ducting, ducting must be as straight, smooth and taut as possible. Coil is iced Coil is iced See below. Thermostat set point is too low Raise set point. Improper air flow Remove any obstructions in return air stream.
Operation / Installation Manual – FCF 5000, 9000, 12000, 16000, 24000 Maintenance Reversing Valves Reverse cycle units have a reversing valve; the valve must be energized periodically to keep the internal parts moving freely. To do this, switch the air conditioning unit into heat mode 2-3 cycles per month. Seawater Strainer Ensure that your pump receives adequate seawater flow by regularly cleaning the strainer basket. Periodically check the overboard discharge for a steady stream of water.
Operation / Installation Manual – FCF 5000, 9000, 12000, 16000, 24000 Winterization There are several methods of winterization, some of which work better than others. There are various methods employed using a 50/50 non-polluting biodegradable anti-freeze/water solution. Any method that causes the anti-freeze solution to flow downward is the method of choice. By this, the anti-freeze solution will displace any water trapped and eliminate the possibility of freezing in hidden areas.
Operation / Installation Manual – FCF 5000, 9000, 12000, 16000, 24000 Unit Dimensions & Technical Specifications Unit Dimensions & Technical Specifications BTU Capacity 5000 9000 12000 16000 24000 Capacity in kW 1.5 2.6 3.5 4.6 7.5 Voltage (V) 115 230 230 115 230 230 115 230 230 115 230 230 115 115 Soft 230 230 Frequency (Hz) 60 50 60 60 50 60 60 50 60 60 50 60 60 60 50 60 Running Current (A) 5.8 3.8 2.5 8.3 4.9 4.6 11 4.6 5.6 12.4 6.2 8.4 20.5 20.
Operation / Installation Manual – FCF 5000, 9000, 12000, 16000, 24000 Limited Warranty This product comes with a 24 month limited warranty from the date of purchase. For warranty policy details, visit http://www.techwebasto.com. To obtain warranty service, contact a customer service representative at: (800) 860-7866 or e-mail at: info-us@webasto.com. Technical Assistance If you require help, check our technical assistance website at http://www.techwebasto.
NOTES
Webasto Product N.A., Inc. Technical Assistance Hotline Phone: (800) 860-7866 Outside U.S. (810) 593-6000 www.webasto.us www.techwebasto.com Original 7/2006 | Rev.