Unit Dimensions & Technical Specifications
Unit Dimensions & Technical Specifications
BTU Capacity 5000 9000 12000 16000 24000
Capacity in kW 1.5 2.6 3.5 4.6 7.5
Voltage (V) 115 230 230 115 230 230 115 230 230 115 230 230 115 115 Soft
230 230
Frequency (Hz) 60 50 60 60 50 60 60 50 60 60 50 60 60 60 50 60
Running Current (A) 5.8 3.8 2.5 8.3 4.9 4.6 11 4.6 5.6 12.4 6.2 8.4 20.5 20.4 8.6 12.5
Starting surge (A) 23.5 15.5 13.5 36.5 16.5 18 45 29 25 54.5 25.5 26.5 90.5 39 41 46
Refrigerant R410A R410A R410A R410A R410A
Net Weight (kg) 24 27 33 34 60
Shipping weight (kg) 28 32 38 39.5 68
Blower Output (m
3
/h) 300 450 550 750 1100
Dia. Cupro (mm) 16 16 16 16 16
H (mm) 295 310 330 330 382
H1 (mm) 260 260 290 290 326
H2 (mm) 54 54 54 54 56
P (mm) 285 380 380 450 595
D (mm) 100 100 125 125 127
L (mm) 408 408 438 454 529
L1 (mm) 280 280 280 295 382
L2 (mm) 380 395 410 440 519
Suggest Breaker (A) 15 10 10 20 15 15 30 25 25 40 30 30
50 50 50 50
Internal Fuse 3.15 AL 250V 3.15 AL 250V 3.15 AL 250V 3.15 AL 250V
3.15 AL 250V
This data is subject to change without notice; please refer to the data on the nameplate.