Specifications
Operation / Installation Manual – FCF 5,000, 9,000, 12,000, 16,000
Page 27
Unit Dimensions & Technical Specifications
Unit Dimensions & Technical Specifications
BTU Capacity
5000
9000
12000
16000
Capacity in kW
1.5
2.6
3.5
4.6
Voltage
115V/230V
115V/230V
115V/230V
115V/230V
Frequency
60Hz
60Hz
60Hz
60Hz
Aver. Load Amps
4.8A/2.2A
7.2A/3.5A
9.8A/4.6A
10.5A/5.6A
Starting surge
13A/6A
19A/9A
26A/13A
28A/15A
Refrigerant
R22
R22
R22
R22
Net Weight
24kg
27kg
33kg
34kg
Shipping weight
28kg
32kg
38.5kg
39.5kg
Blower Output
350/300m
3
/h
450m
3
/h
550m
3
/h
750m
3
/h
Dia. Cupro
16mm
16mm
16mm
16mm
H(mm)
295
310
330
330
H1(mm)
260
260
290
290
H2(mm)
54
54
54
54
P(mm)
285
380
380
450
D(mm)
100
100
125
125
L(mm)
408
408
438
454
L1(mm)
280
280
280
295
L2(mm)
380
395
410
440
Suggest Breaker
16A/16A
25A/16A
32A/16A
40A/16A
NOTE: The data is subject to change without notice; please refer to the data on the nameplate.