Technical data

6.Function Test  DBW 2010 / 2012 / 2020 / 2022 / 300 / 350 
602 
-  Loosen the tightening bolt (refer to Figure) and push 
the adjustment ring with the squeezing bolt until the 
nominal value has been reached. 
-  Squeeze the bolt with 1.0 + 0.5 Nm and put security 
varnish on it. 
WARNING 
The CO
2
 setting depends on the viscosity and geodetic 
altitude (0.1 % for each 100 m). In the case that the CO
2
value cannot be adjusted according to the rules, act as 
follows: 
-  Check if there is any damage on the air side of 
the burner head and replace if there is a damage. 
-  Check the pressure of the fuel pump and replace 
the pump if necessary. 
-  Replace the nozzle 
-  Measure the revolution of the burner engine 
-  Check to see whether or not the assembly at the 
cable joints is correct. 
6.3  Testing the individual elements 
6.3.1  The resistance check of the heat sensor (only 
the heating devices equipped with the control 
device 1563/64)
The heat sensor should exhibit the values shown in the 
graphic below at the electrical test conducted with the 
digital multimeter. The resistance measurement should 
be carried out preferably at 20 
0
C and approximately at 
100 
0
C (the sensor will be immersed in water). 
Squeezing bolt 
WARNING 
The suction clam
p
in
g
 sleeve 
can be rotated by 180
0
. 
Water tem
p
erature 
0
C 
Resistance (Ohm) 