Technical data

DBW 2010 / 2012 / 2020 / 2022 / 300 / 350 8 Service Tasks
807
8.7.4 The replacement of the thermal fuse
WARNING
The acts of replacement regarding the thermal sensor are
the same whether it is mounted or dismounted.
The act of replacement will be carried out according to
9.2.3.
DANGER
The excessive pressure in the cooling system must be
reduced by opening the cooling connection in the course
of the replacement of the thermal fuser when the heating
device equipped with the control device 1563/64 is
mounted.
If necessary, wait as an additional measure for the
heating device to cool down and keep a pot ready.
8.7.5 The replacement of the regulation
thermostat
WARNING
The acts of replacement regarding the regulation
thermostat are the same whether it is mounted or
dismounted.
The act of replacement will be carried out according to
9.2.4.
8.7.6 The replacement of the fan thermostat
WARNING
The acts of replacement regarding the fan thermostat are
the same whether it is mounted or dismounted.
The act of replacement will be carried out according to
9.2.5.
8.7.7 The replacement of the thermal fuse
element
WARNING
The acts of replacement regarding the thermal fuse
element are the same whether it is mounted or
dismounted.
The act of replacement will be carried out according to
9.2.6.
8.7.8 The replacement of the burner head
WARNING
The acts of replacement regarding the burner head are
the same whether it is mounted or dismounted.
The act of replacement will be carried out according to
9.2.8.
DANGER
The induction bobbin works with high voltage. The cable
bunch sockets must be separated from the control device
before the burner head will be replaced because
otherwise there is danger of death.
8.7.9 The replacement of the induction bobbin
WARNING
The acts of replacement regarding the induction bobbin
are the same whether it is mounted or dismounted.
The act of replacement will be carried out according to
09.02.2012.
DANGER
The induction bobbin works with high voltage. The cable
bunch sockets must be separated from the control device
before the burner head will be replaced because
otherwise there is danger of death.
8.7.10 The replacement of the flame regulator
WARNING
The acts of replacement regarding the flame regulator are
the same whether it is mounted or dismounted.
The act of replacement will be carried out according to
09.02.2013.
DANGER
The induction bobbin works with high voltage. The cable
bunch sockets must be separated from the control device
before the burner head will be replaced because
otherwise there is danger of death.
8.7.11 The replacement of the combustion
chamber
WARNING
The acts of replacement regarding the combustion
chamber are the same whether it is mounted or
dismounted.
The act of replacement will be carried out according to
09.02.2017.
DANGER
The induction bobbin works with high voltage. The cable
bunch sockets must be separated from the control device
before the burner head will be replaced because
otherwise there is danger of death.