Technical data

9.The repair DBW 2010 / 2012 / 2020 / 2022 / 300 / 350
906
Pos. Definition Note
A1 Heating device
A2 Control device SG 1553
B Socket connection, with 6 pins
B5 Thermostat For the pre-heating of the nozzle block
F1 Fuse Flat fuse DIN 72581
F2 Fuse Flat fuse DIN 72581
F3 Fuse 16 A (12 V); 8 A (24 V) Flat fuse DIN 72581
G Battery
H1 Lamp Work indicator
K6 Relay For the pre-heating of the nozzle block
R2 Heating cartridge For the pre-heating of the nozzle block
S1 Switch On/off
S2 Switch on the water valve
W2 Cable bunch
X1 Socket connection, with 4 pins
The electrical Connection