User's Manual

WebEye WebEye B101B101
User’s Guide
11
2) Configuring Administrators Conditions
To access the WebEye’s Administrator’s Page from the Setup Menu, enter the admin.’s password and click
the “Start Configuration” button.
To configure several WebEyes simultaneously , follow the Steps below. However, some information such as
“Date and Time at System,” “Serial Number,” and “IP Configuration at Network,” will not change. “Date and
Time at System” and “IP Configuration at Network” can be changed in the Setup program. The“Serial
Number”never changes.
After configuring all of the conditions, close WebEye homepage.
Click Save button.
Save the information to a directory.
Select another WebEye on the local network and type in the administrators password.
Click Start Configuration and “Load” buttons in turns.
A Loading Completed message will appear on the window when the procedure is completed.
3. Assigning IP Address with ARP command
1) Using ARP in Windows 98 and NT
When using WebEye with Windows 98 and Windows NT, follow the steps below.
Open a DOS window and type the following commands.
arp -s <WebEye IP address> <WebEye Ethernet address>
ping -t <WebEye IP address>
Example
arp -s 192 .168.1.3 00-40-8c-10-00-86
ping -t 192.168.1.3
2) Using ARP in Windows 95
When using WebEye with Windows 95, follow the s teps below.
Open a DOS window and type the following commands.
arp -s <WebEye IP add.> <WebEye Ethernet add.> <my PC IP add.>
ping <WebEye IP address>
Example
arp -s 192 .168.1.3 00-40-8c-10-00-86 192.168.1.2
ping 192.168.1.3