This button will allow user to save and restore the WebMux configuration to and
from their management workstation. See later chapter for details.
Setup Button
This button brings up the “Administration Setup” page. "Super User" login is
required to access this page. See related section later for details.
Show Event
This button will display all the events since WebMux last reboot. The event
includes server failure or state change.
Logout
It is not recommended to leave the management browser login unattended. Click
the Logout button to close the session. The “Login” screen will re-appear.
Pause
The status screen automatically refreshes frequently to provide most up to date
status. You can use the Pause button to freeze the auto refresh.
Resume
After the Pause button being pushed, the button will change to Resume and the
auto refresh stopped. Click the Resume button to restart the auto refresh.
Adjusting Timeout for Each Service
Click on the service type of each farm will allow you to change the timeout value
of layer 7 testing for each different service. Please note this change is global that
will affect all the farms using the same type of service. For example, the default
timeout for checking HTTP protocol alive or not is 5 seconds. If web server does
not respond to the WebMux protocol chat within 5 seconds, WebMux will declare
that server is dead and switch that server out from service and notify the operator
through email or pager. However, if your web server did not really dead but for
some reason not responding to the checking request, WebMux would false
alarm. To avoid this, user can change the timeout value to a larger value. Many
times, servers can not resolve the IP address for the back end of WebMux IP
address could cause server not responding to WebMux’s protocol checking.
Adding the WebMux server LAN IP address and server LAN gateway address to
the name resolution table will help resolve this problem. Please read the Q&A
section for more information.