User`s manual
Operation
32   800032-01 Rev. G  www.wegener.com
Home and 
default 
screens
The home screen appears on the LCD by default at boot up. During operation, the user may 
return to the home screen at any time, from any location in the menu hierarchy, by pressing 
the Escape (
ESC) button repeatedly (or pressing and holding it). Regardless of the current 
location within the LCD menu hierarchy, if no front-panel keypress is made for more than 5 
minutes, the LCD reverts to the default screen. Usually, this is the home screen. However, 
under some conditions (two are described below), another screen becomes the default. If 
more than one of these conditions exist simultaneously, priority is given in the order listed.
Note:  Regardless of which screen is the current default, the user may still access all 
available screens using the left- and right-arrow, 
ENT and ESC buttons.)
Download Screen as default
If the Unity 4600 is in an ACCEPT PACKETS Download state, then the Download screen 
becomes default.
Unit Status/History
Allows user to access unit status and diagnostics. Typical items 
located under this menu include:
 Current unit state
 Signal Quality
 Last commanded and last successful unit settings
 Program Analysis
 Local audio/video decompression history
 Network control status/history
 Current LAN settings
 Encryption settings
 Unit internal temperature
 Option module presence/status
 Unit information screen (including software version)
 Control to clear diagnostics
Unit Setup
Allows user to control unit. Typical controls located under this menu 
include:
 Set permanent unit settings (tuning, program, audio selection)
 Add/edit/move/delete Presets
 NTSC Pedestal
 Buffer control (PCR offset)
 Audio attenuation
 Audio front-panel monitor select
 Muting
 VBI line re-insertion enable
 Recovery mode timeouts
 Serial port setup
 LNB LO frequency set
 LNB DC power set
 User cue relays
 Signal quality indicator thresholds
 Minimum alarm/warning indication times
 LAN settings
 NVRAM operations
 Alarm (history) latching enable
 Program Mapping Ghost PID pass list
 Current unit software selection
 Unit label edit
 Unit reset
Screen Name Functions/Applications