addr: IP address formatted as n1:n2:n3:n4 where nn1, n2, n3, and n4 are integers between 0 and 
255.
IP address of local Mail Relay server, if any. A Local Control Command (available from the terminal 
regardless of "Local Control Enable/Disable" commands from the network).
RPATH SEND
Command ordering IRD to immediately send a Return Path report. A Local Control Command (available 
from the terminal regardless of "Local Control Enable/Disable" commands from the 
network).
RPATH TO username@addr
username: Legal string of keyboard characters without white space.
addr: IP address formatted as 
n1:n2:n3:n4 where nn1, n2, n3, and n4 are integers between 0 and 
255.
Email address destination for Return Path reporting. A Local Control Command (available from the 
terminal regardless of "Local Control Enable/Disable" commands from the network).
SAVENV
Saves all the current global and Unit Setting NV parameters (in NVRAM) to the Flash memory space 
designated as 
BACKUP. 
Note: Some unit-set parameters, which would not make sense to “back up”, may not be saved. 
A Local Control Command (available from the terminal regardless of "Local Control Enable/Disable" 
commands from the network).
SAVEP [entry#] [channel_label]
entry#: A Preset Table Entry number or the text, PERM. If a preset entry, must be equal to a number 
between 
1 and N inclusive, where N is the highest entry number.
channel_label:Channel Label associated with a unit setting or a Preset Table entry. If attempting to 
supply the 
channel_label parameter alone, a value of PERM is not legal. Parameter must be 
a string of continuous non-white-space keyboard characters. Unit will truncate user input to 
10 characters.
Command saves current Unit Settings to a Preset Table entry, or if 
entry# is PERM, a current Transient 
Setting is loaded into the unit's Permanent unit setting. Those metadata fields in the 
extended Preset Entry that have no analog in the current Unit setting will be populated with 
spec defaults. User must use 
ADDE command to set those fields.
If entry# is supplied alone, current unit settings are written to that entry, overwriting existing data if it had 
been in use. If channel_label is supplied alone, and if that same Label already appears at 
a used Preset Table entry, then the current unit settings overwrite that old Preset data. If 
channel_label is supplied alone and no used Preset has that Label, then the current 
settings are written to the lowest empty Preset Table entry and then given that same Label. 
If both entry# and channel_label parameters are supplied, then the current unit settings are 
written at that Entry (overwriting existing data if any) and that entry is supplied that same 
Label (equal to channel_label).