User`s manual
 www.wegener.com 800032-01 Rev. G  55
Unity 4600 User’s Manual 
Low RF level There is carrier lock, but the RF signal level is too low.
New PAT with changes The version number on the Program Allocation table has 
changed and a new program lineup has been submitted. 
Changes have been made on uplink transport mux.
New PMT with changes The version number on one or more of the Program Map 
Tables has changed with a new PID lineup submitted. 
Changes have been made on uplink transport mux.
No ASI stream Corrupt or missing input ASI stream. Only applicable if ASI 
input is available and selected. Check connection and source.
No audio for Port N
(N=audio port number)
No "free" otherwise-unassigned audio can be allocated to 
wildcard-assigned port 
N
. There may be fewer audio PES 
streams than installed audio ports. If so, explicitly assign a 
desired language descriptor to this audio port.
No Carrier Lock Carrier lock cannot (or has not) been acquired and 
maintained. Check that requested settings are correct. Check 
RF level indication and RF connection. For new installations, 
check antenna pointing and polarization.
No COMPEL Data traffic is detected at designated packet ID (PID) for 
COMPEL
®
. However, no valid COMPEL messages have 
been detected during the last two minutes. There may be no 
connection to the network. If required to maintain a 
connection, the unit will eventually attempt an automatic 
recovery to a backup preset. To debug, check that the 
COMPEL system at the uplink is functional and that the data 
connection to inserter (such as UMX5010) is good. Also 
check for fault indications or functional problems at 
UMX5010.
No COMPEL PID No traffic detected at designated packet ID (PID) for 
COMPEL, so no connection is made to the network. The 
COMPEL PID setting in the unit may be incorrect. Also see 
"No COMPEL indication".
No Def for mapping ASI transport output bears no program content because an 
Output Definition Table has not been loaded from the 
network. Contact network TOC.
No DHCP server found IRD is required to get IP settings from DHCP server but none 
are detected on the LAN.
No genlock sync IRD supports and has genlock option installed and enabled, 
but no video reference sync is detected.
No ID Tag found
No carrier ID tags in COMPEL
®
 stream. Set IRD not to 
expect ID tags or check uplink UMX5010.
No KMS stream No KMS stream detected since transport stream acquisition. 
Unit will not be authorized if not connected to the KMS 
stream. Check that KMS PID is set correctly in unit. If okay, 
check the uplink.
No LAN detected No Ethernet LAN connection. Check LEDs on rear and check 
other devices on the LAN.
LCD Alarm or Warning 
Message
Meaning / Possible Cause