Operating Instructions

13
4.3.1 Cooling system
Capacity: 40 Liters
1. Make sure the main drain valve of the fresh water cooling system (above the oil
lter mounting) is closed properly. Refer gure 4.1
Figure 4.1
2. The coolant can be lled from the heat exchanger. Remove the cap provided
on the top (gure 4.2) and slowly ll the cooling system with recommended
coolant (gure 4.3). Slowly lling the coolant will help the air to escape without
trapping in the system.
For more details about coolant specication, refer section VI.
Figure 4.2 Figure 4.3