Operating Instructions

32
Run the engine for a short time, during running check and ensure no leakage from
the lter sealing and from the oil drain plug refer gure 5.7
OK
Figure 5.7
Stop the engine; check the tightness of lter for reliability, if necessary. Measure the
oil level with the help of the oil dipstick.
To get correct oil level, always check it 5 to 10 minutes after
stopping the engine
5.7.5 Cleaning of oil gas separator
Oil gas separator is functioning as a ventilator for crank case to release the ugases
by controlling the oil wastage/ consumption/ spillage. Periodic maintenance and
monitoring will help us to understand the health of combusting system.
5.7.6 Replacement of fuel lter
Use the lter wrench to loosen the lter and remove it by hand. Use a suitable tray
under the lter location to collect diesel spillage before removing the lter. Loosen
and remove the lter. Refer gure 5.8 & 5.9.
Figure 5.8 Figure 5.9
Let the fuel drain completely from the lter housing. Wipe the sealing surface with
a clean cloth, and apply fresh oil to the seal ring, then tighten new diesel lter with
the lter wrench