Datasheet

Datenblatt
OMNIMATE Signal - series BL/SL 3.50
BLZF 3.50/04/180F SN OR BX
Weidmüller Interface GmbH & Co. KG
Klingenbergstraße 16
D-32758 Detmold
Germany
Fon: +49 5231 14-0
Fax: +49 5231 14-292083
www.weidmueller.com
Technische Daten
Erstellungs-Datum January 13, 2014 7:53:02 PM CET
Katalogstand xx.xx.xxxx / Technische Änderungen vorbehalten 3
CSA rating data
Institute (CSA)
Rated voltage (Use group B)
300 V
Rated current (use group B) 10 A
Rated voltage (use group D) 300 V
Rated current (use group D) 10 A
Wire cross-section, AWG, min.
AWG 26
Wire cross-section, AWG, max. AWG 14
UL 1059 rating data
Institute (UR)
Rated voltage (use group B)
300 V
Rated current (use group B) 10 A
Rated voltage (use group D) 300 V
Rated current (use group D) 10 A
Wire cross-section, AWG, min.
AWG 26
Wire cross-section, AWG, max. AWG 14
Classifications
ETIM 3.0 EC001284
UNSPSC 30-21-18-10
eClass 5.1 27-26-07-04
eClass 6.2
27-26-07-04
eClass 7.1 27-44-04-02
Notes
Notes Additional colours on request
Gold-plated contact surfaces on request
Rated current related to rated cross-section & min. No. of poles.
Max. outer diameter of the conductor: 2.9 mm
Wire end ferrule without plastic collar to DIN 46228/1
Wire end ferrule with plastic collar to DIN 46228/4
Crimp shape A for wire-end ferrules with crimping tools PZ 1,5 (order no. 9005990000) or PZ 6/5 (order no.
9011460000) for larger wire cross-sections recommended.
P on drawing = pitch
Rated data refer only to the component itself. Clearance and creepage distances to other components are to
be designed in accordance with the relevant application standards.
Approvals
Approvals
ROHS Conform