Brochure/Catalogue

Selection table
Selection table
Order No. Product
Input
Width
Output
Conguration
Auxiliary
power
Rated
voltage
Isolation
Connection system
Special characteristics
Amount
0...20 mA
4...20 mA
0...10 V
0...5 V
TC
RTD
Frequency
Miscellaneous
Sensor feed
Amount
0...20 mA
4...20 mA
0...10 V
Relay
Miscellaneous
Signal converters and monitoring components – ACT20P
Signal converters
7760054114 ACT20P-CI-CO-S 1 X X 2-/3-wire transmitter, HART
®
transparent X 12.5 mm 1 X X - 24 V DC 300 V 3-way S HART
®
transparent
2489680000 ACT20P-CI-CO-P 1 X X 2-/3-wire transmitter, HART
®
transparent X 12.5 mm 1 X X - 24 V DC 300 V 3-way P HART
®
transparent
7760054117 ACT20P-2CI-2CO-12-S 2 X X 4-wire sensor, HART
®
transparent 12.5 mm 2 X X - 24 V DC 300 V 3-way S HART
®
transparent
2489730000 ACT20P-2CI-2CO-12-P 2 X X 4-wire sensor, HART
®
transparent 12.5 mm 2 X X - 24 V DC 300 V 3-way P HART
®
transparent
1540010000 ACT20P-CI-VO-S 1 X X 2-/3-/4-wire sensor X 12.5 mm 1 X - 24 V DC 300 V 3-way S
2489740000 ACT20P-CI-VO-P 1 X X 2-/3-/4-wire sensor X 12.5 mm 1 X - 24 V DC 300 V 3-way P
7760054306 ACT20P-VM-AO-S 1 0...440 V AC, 0...660 V DC 22.5 mm 1 X X X Software 24...240 V UC 600 V 3-way S
Passive isolators
7760054123 ACT20P-CI-CO-ILP-S 1 X X 4-wire sensor X 12.5 mm 1 X X - input loop 300 V 2-way S
7760054124 ACT20P-2CI-2CO-ILP-S 2 X X 4-wire sensor X 12.5 mm 2 X X - input loop 300 V 4-way S
7760054122 ACT20P-CI-2CO-OLP-S 1 X 4-wire sensor X 12.5 mm 2 X - output loop 300 V 3-way S
7760054118 ACT20P-CI1-CO-OLP-S 1 X 4-wire sensor X 12.5 mm 1 X - output loop 300 V 2-way S
7760054119 ACT20P-CI2-CO-OLP-S 1 X 4-wire sensor X 12.5 mm 1 X - output loop 300 V 2-way S
7760054121 ACT20P-VI-CO-OLP-S 1 X 4-wire sensor X 12.5 mm 1 X - output loop 300 V 2-way S
7760054120 ACT20P-VI1-CO-OLP-S 1 X 4-wire sensor X 12.5 mm 1 X - output loop 300 V 2-way S
7760054122 ACT20P-CI-2CO-OLP-S 1 X 4-wire sensor X 12.5 mm 2 X - output loop 300 V 4-way S
Signal splitters
7760054115 ACT20P-CI-2CO-S 1 X X 2-/3-/4-wire sensor, HART
®
transparent X 12.5 mm 2 X X - 24 V DC 300 V 4-way S HART
®
transparent
2489710000 ACT20P-CI-2CO-P 1 X X 2-/3-/4-wire sensor, HART
®
transparent X 12.5 mm 2 X X - 24 V DC 300 V 4-way P HART
®
transparent
Temperature transducer
7760054305 ACT20P-TMR-RTI-S 1 X PT100 22.5 mm 2 X 2 x relay outputs (limit value) Software, Display 20...264 V UC 300 V 5-way S
2448100000 ACT20P-PRO-RTCI-AO-DO-S 1 X X RTD, SRTD, Pot, mV, resistance X 12.5 mm 1 X X X analogue and NPN output, Limit value Display, Button 24...240 V UC 300 V 3-way S
2448110000 ACT20P-PRO-RTCI-AO-DO-P 1 X X RTD, SRTD, Pot, mV, resistance X 12.5 mm 1 X X X analogue and NPN output, Limit value Display, Button 24...240 V UC 300 V 5-way P
7940045760 ACT20P-UI-2RCO-DC-S 1 X X X X X X ± 25 mA, ± 5 A DC, ± 30 V DC, ± 300 V DC, potentiometer, resistance X 22.5 mm 1 X 2 x Limit value relay output Software, Display 9...60 V DC 300 V 5-way S
2456840000 ACT20P-UI-2RCO-DC-P 1 X X X X X X ± 25 mA, ± 5 A DC, ± 30 V DC, ± 300 V DC, potentiometer, resistance X 22.5 mm 1 X 2 x Limit value relay output Software, Display 9...60 V DC 300 V 5-way P
1238910000 ACT20P-UI-2RCO-AC-S 1 X X X X X X ± 25 mA, ± 5 A DC, ± 30 V DC, ± 300 V DC, potentiometer, resistance X 22.5 mm 1 X 2 x Limit value relay output Software, Display 90...264 V AC 300 V 5-way S
2495690000 ACT20P-UI-2RCO-AC-P 1 X X X X X X ± 25 mA, ± 5 A DC, ± 30 V DC, ± 300 V DC, potentiometer, resistance X 22.5 mm 1 X 2 x Limit value relay output Software, Display 90...264 V AC 300 V 5-way P
Measurement and monitoring relays
7760054164 ACT20P-VMR-1PH-H-S 1 1 phase 0...400 V AC/DC 22.5 mm 2 X 2 x Limit value relay output DIP switch, potentiometer 20...240 V UC 300 V 5-way S
7760054165 ACT20P-VMR-3PH-ILP-H-S 1 3 phases 180...500 V AC 22.5 mm 2 X 2 x Limit value relay output DIP switch, potentiometer Input loop 600 V 5-way S
Current measuring transducers
2044850000 ACT20P-CML-10-AO-RC-S 1 0...1/5/10 A AC/DC 17.5 mm 1 X X X X ± 10 V, ± 20 mA, Limit value relays DIP switch, potentiometer 24 V DC 300 V 4-way S Power cable can be connected to the terminals
2489910000 ACT20P-CML-10-AO-RC-P 1 0...1/5/10 A AC/DC 17.5 mm 1 X X X X ± 10 V, ± 20 mA, Limit value relays DIP switch, potentiometer 24 V DC 300 V 4-way P Power cable can be connected to the terminals
1510470000 ACT20P-CMT-10-AO-RC-S 1 0...5/10 A AC/DC 22.5 mm 1 X X X X ± 10 V, ± 20 mA, Limit value relays DIP switch, potentiometer 24 V DC 300 V 4-way S Through hole current converter
1510540000 ACT20P-CMT-30-AO-RC-S 1 0...20/25/30 A AC/DC 22.5 mm 1 X X X X ± 10 V, ± 20 mA, Limit value relays DIP switch, potentiometer 24 V DC 300 V 4-way S Through hole current converter
1510440000 ACT20P-CMT-60-AO-RC-S 1 0...40/50/60 A AC/DC 22.5 mm 1 X X X X ± 10 V, ± 20 mA, Limit value relays DIP switch, potentiometer 24 V DC 300 V 4-way S Through hole current converter
1510390000 ACT20P-CMT-60-RC-S 1 0...40/50/60 A AC/DC 22.5 mm 1 X Limit value relay output DIP switch, potentiometer 24 V DC 300 V 3-way S Through hole current converter
1510330000 ACT20P-CMT-10-AO-RC-P 1 0...5/10 A AC/DC 22.5 mm 1 X X X X ± 10 V, ± 20 mA, Limit value relays DIP switch, potentiometer 24 V DC 300 V 4-way P Through hole current converter
1510320000 ACT20P-CMT-30-AO-RC-P 1 0...20/25/30 A AC/DC 22.5 mm 1 X X X X ± 10 V, ± 20 mA, Limit value relays DIP switch, potentiometer 24 V DC 300 V 4-way P Through hole current converter
1510290000 ACT20P-CMT-60-AO-RC-P 1 0...40/50/60 A AC/DC 22.5 mm 1 X X X X ± 10 V, ± 20 mA, Limit value relays DIP switch, potentiometer 24 V DC 300 V 4-way P Through hole current converter
1510280000 ACT20P-CMT-60-RC-P 0...40/50/60 A AC/DC 22.5 mm 1 X Limit value relay output DIP switch, potentiometer 24 V DC 300 V 3-way P Through hole current converter
Bridge measuring transducers
1067250000 ACT20P-BRIDGE-S 1 4-,6-wire strain gauge X 22.5 mm 1 X X X Reset button (TARE) DIP switch, button 10...60 V DC 300 V 3-way S
2456820000 ACT20P-BRIDGE-P 1 4-,6-wire strain gauge X 22.5 mm 1 X X X Reset button (TARE) DIP switch, button 10...60 V DC 300 V 3-way P
Universal measurement transducers
1481970000 ACT20P-PRO DCDC II-S 1 X X X X ± 100 mA, ± 300 V DC X 12.5 mm 1 X X X ± 10 V, ± 20 mA Display, DIP switch, button 24 V - 230 V AC/DC 600 V 3-way S aktiv or passiv output
1481960000 ACT20P-PRO DCDC II-P 1 X X X X ± 100 mA, ± 300 V DC X 12.5 mm 1 X X X ± 10 V, ± 20 mA Display, DIP switch, button 24 V - 230 V AC/DC 600 V 3-way P aktiv or passiv output
1453210000 ACT20P-UI-AO-DO-LP-S 1 X X X X X X ± 25 mA, ± 5 A DC, ± 28 V DC, ± 300 V DC, 300 V AC X 12.5 mm 1 X NPN output, Limit value Software output loop 300 V 3-way S Output Loop powered
2456850000 ACT20P-UI-AO-DO-LP-P 1 X X X X X X ± 25 mA, ± 5 A DC, ± 28 V DC, ± 300 V DC, 300 V AC X 12.5 mm 1 X NPN output, Limit value Software output loop 300 V 3-way P Output Loop powered
1477420000 ACT20P-AI-AO-DC-S 1 X X X X 0...11 V, 0...22 mA X 12.5 mm 1 X X X 0...11V, 0...22mA DIP switch, button, LED 12...60 V DC 300 V 3-way S
2456860000 ACT20P-AI-AO-DC-P 1 X X X X 0...11 V, 0...22 mA X 12.5 mm 1 X X X 0...11V, 0...22mA DIP switch, button, LED 12...60 V DC 300 V 3-way P
Connection system: S = screw / Z = tension clamp / P = Push In, ILP = Input Loop Powered, OLP = Output Loop Powered
D.52729490000
Signal converters and monitoring
components – ACT20P
D