Brochure/Catalogue

D
D.22 2729490000
Configurable
Bridge measuring transducer for reading from load cells
3-way isolation
Supplies measuring bridges up to 4 x 350 Ω
Simple calibration of the tare weight using external
switch or PLC input
Input and output ranges adjustable via DIP switch
Technical data
Input
Bridge sensitivity
Input measurement range
Sensor
Sensor supply
Bridge supply voltage
Output
Type
Output voltage / Output current
Load impedance, voltage/current
General data
Configuration
Voltage supply
Power consumption
Linearity
Repeat accuracy
Humidity
Temperature coefficient
Long-term drift
Step response time
Ambient temperature
Approvals
Insulation coordination
Standards
EMC standards
Rated voltage
Pollution degree
Overvoltage category
Insulation voltage
Dimensions
Clamping range (nominal / min. / max.) mm²
Depth x width x height mm
Note
Ordering data
Connection type
Screw connection
PUSH IN connection
Note
Accessories
Note
ACT20P-BRIDGE-S
V/I
PS
+
2323
2424
53
54
11
22
14
12
13
21
+
excitation +
sense -sens
excitation -
signal +
signal -
sense +
Strain
Gauge
10...60 V DC
44
41
42
43
mA test point +
mA test point -
0...10 V
I
0/4...20 mA
Tare
+
--
-
1.0 mV / V to 5.0 mV / V
± 10 mV / ± 20 mV / ± 30 mV / ± 50 mV (adjustable)
Resistance measuring bridge, Total resistance of all parallel resistance
measuring bridges: min. 87Ω
120 mA @ 10 V (= 4 x 350 Ω bridge resistors)
5 V or 10 V
Voltage and current output (configurable)
0…11 V (adjustable) / 0…22 mA (adjustable)
600 Ω / ≤ 600 Ω
DIP switch and button
10…60 V DC
3 W @ 24 V DC
Typically ± 0.05 % of signal range
± 0.05 % of final value
10…90 %, no condensation
typ. 0.005 % / °C
0.1 % / 10.000 h
< 400 ms (10…90 %)
-40 °C...70 °C
CE; EAC
DIN EN 61010-1, DIN EN 61000-4-2
EN 61326
300 V
eff
2
III
5.7 kV (input / output, input / supply)
Screw connection PUSH IN
2.5 / 0.5 / 2.5
113.6 / 22.5 / 119.2 113.6 / 22.5 / 127.1
Type Qty. Order No.
ACT20P-BRIDGE-S 1 1067250000
ACT20P-BRIDGE-P 1 2456820000
ont panel DIP Switch settings
Switch Action if On Action if Off
1 10 V Excitation 5 V Excitation
2 mA Output Voltage Output
3 10 mV Span
4 20 mV Span Turn off for other ranges
5 30 mV Span
6 50 mV Span
7
4-wire Measurement 6-wire Measurement
8
s
Terminal Signal
11 Signal −
Input signal
12 Signal +
13 Sense +
14 Sense −
Bridge Excitation Voltage
21 Excitation +
22 Excitation −
23 Tare +
External Tare switch
24 Tare
41 mA Output −
42 Output +
43 mA-Test Point − Output signal
44 Voltage Output
44 mA-Test Point +
54 +
Power Supply
53
Bridge measuring transducers
Signal converters and monitoring
components – ACT20P