User Documentation

Appendix F. Installation Drawings ACT20X-SAI-HAO (HART-transparent Driver)
198 1066530000/08/12-2018
Terminal (41, 42, 43, 44) and (51, 52, 53, 54)
Supply / Current Input
U
m
253 V, max. 400 Hz
Terminal (51, 52)
Supply
Voltage 19.231.2 V DC
Terminal (53, 54)
Status Relay
Non Hazardous
Location
Zone 2 Installation
Voltage max. 125 V AC / 110 V DC 32 V AC / 32 V DC
Current max. 0.5 A AC / 0.3 A DC 0.5 A AC / 1 A DC
Power max. 62.5 VA / 32 W 16 VA / 32 W