Brochure/Catalogue

Universal measurement transducers
Output -powered universal measurement transducers
The ACT20X-HUI-SAO-LP is a universal input, isolating signal converter. This model processes temperature
signals from PT100 sensors and thermocouples as well as DC voltage and current signals (mA) from the
hazardous area. The 12.5 mm wide module is powered through it‘s 4-20 mA output.
EX area Zone 0, 1, 2, 20, 21, 22 Safe area Zone 2 / FM Class 1, Division 2
Input signals Output signals
41
42
11
12
21
22
- Loop Powered (4-20 mA)
+Loop Powered (4-20 mA)
-20 ≤ Ta ≤ +60 °C
Volt
POT
RTD/RES
3-wire
2-wire
TC
mV mA
+
+
+
-
Zone 0, 1, 2, 20, 21, 22 /
Cl. I/II/III, div. 1 gr. A-G
Zone 2 / FM Cl. 1, div. 2,
gr. A-D or safe area
Ex label
ATEX
U
o
5.88 V
II 3 G Ex nA nC IIC T4 I
o
3.1 mA
II (1) G [Ex ia] IIC/IIB/IIA P
o
4.6 mW
II (1) D [Ex iaD] C
i
0.001 μF
IECEx L
i
negligible
Ex nA IIC T4 Gc Example:
[Ex ia Ma Ga] I/IIC [Ex ia Da] IIIC IECEx version
(More details in IECEx certicate)
Application example: Temperature measurement in the EX-zone
5HVLVWDQFH
WHPSHUDWXUHVHQVRU
7DQN
=RQH
(;=RQH6DIH=RQH
$&7;+8,6$2
&RQWURO
V\VWHP
P$2XWSXW
,QSXW
FKDQQHO
DFWLYH
Accuracy / temperature coefficients
ACT20X-HUI-SAO-LP
Input Accuracy Temperature
coefcient
Input mA ≤ ±4 μA ≤ ±4 μA / °C
Input Volt ≤ ±20 μV ≤ ±2 μV / °C
Input RTD
Pt100 ≤ ±0.2 °C ≤ ±0.02 °C / °C
Ni100 ≤ ±0.3 °C ≤ ±0.03 °C / °C
Input TC
Type B ≤ ±4.5 °C ≤ ±0.45 °C / °C
Type E, J, K, L, N, T, U ≤ ±1 °C ≤ ±0.1 °C / °C
Type R , S, W3, W5, LR ≤ ±2 °C ≤ ±0.2 °C / °C
Note
\
%
Removable
terminals
(black)
Marker
Removable
terminals
(blue)
C.22 2729490000
Intrinsically safe signal converters – ACT20X