Brochure/Catalogue

D
D.20 2729490000
Current measuring transducer
Measuring and monitoring AC/DC currents
Input/output electrically isolated
Input and output ranges are adjustable
Measurement range extension via external current
transformer
Relay output for limit value alarm with switching
threshold, delay, hysteresis
Technical data
Input
Number of inputs
Input signal
Input frequency
Input measurement range
Output (digital)
Alarm function
Rated switching current
Number of digital outputs
Type
Max. switching voltage, AC
Output (analogue)
Load resistance current
Load resistance voltage
Number of analogue outputs
Output current
Output voltage
General data
Accuracy
Configuration
Step response time
Power consumption, max.
Temperature coefficient
Voltage supply
Insulation coordination
EMC standards
Impulse withstand voltage
Galvanic isolation
Insulation voltage
Test voltage
Overvoltage category
Dimensions
Clamping range (nominal / min. / max.) mm²
Depth / Width / Height mm
Note
Ordering data
Connection type
Screw connection
PUSH IN connection
Note
Accessories
Note
ACT20P-CML-10-AO-RC-S
1
Power cable can be connected to the terminals
AC: 15…400 Hz (true root mean square), AC: 50 Hz (arithmetic
average)
configurable, 0…1/5/10 A AC (RMS) or DC
Surge current, Under-current, Alarm delay: 0…10 s
2 A
1
Relay, 1 CO contact, normal / inverse adjustment
250 V
≤ 600 Ω
≥ 10 kΩ
1
Adjustable, 0...20 mA, 4...20 mA, -20…+20 mA
Adjustable, 0...10 V, 2…10 V, 0...5 V, 1...5 V, -5…+5 V, -10...+10 V
≤ ±0.3 % @ 1 A ⁄ 5 A, ≤ ±0.6 % @ 10 A
DIP switch and potentiometer
≤ 300 ms (RMS), ≤ 60 ms (AA)
2.2 W
≤ ±100 ppm⁄K @ -25…+55 °C, ≤ ±200 ppm/K @ +55…+70 °C
16,8 V…31,2 V
IEC 61326-1, IEC 61010-2-201
6 kV (1.2/50 µs)
4-way isolator;, between input ⁄ output ⁄ supply ⁄ relay
4 kV
eff
/ 1 min.
4 kV
III
Screw connection PUSH IN
1.5 / 0.5 / 2.5
113.6 / 17.5 / 119.2 114 / 17.5 / 127.1
Type Qty. Order No.
ACT20P-CML-10-AO-RC-S 1 2044850000
ACT20P-CML-10-AO-RC-P 1 2489910000
Output signals
Power supplyOutput signal
Input signal
43
42
41
53
52
51
23
22
21
GND
+16.8...31.2 V DC
Relay
Current Current, voltage
-
+
V
-
+
mA
Output
Output
Supply
Output
OutputInput
Input
Supply
13
12
11
5/10 A
AC/DC
1 A
AC/DC
+
-
+
-
CO
VLJQDO
7LPH
2XWSXW
W
DG
$ODUPGHOD\W
DG
$ODUPGHOD\
+\VWHUHVLV
+LJKDODUPVHWSRLQW
&XUUHQW
VLJQDO
/RZDODUP
7LPH
+\VWHUHVLV
/RZDODUPVHWSRLQW
t t
W!W
DG
WW
DG
W!W
DG
WW
DG
W
2XWSXW
W
DG
$ODUPGHOD\W
DG
$ODUPGHOD\
W
Current measuring transducers
Signal converters and monitoring
components – ACT20P