Approval/Certificate/Document of Conformity

Page 9 of 24 Report No. 250150-TL6-1
IEC 61984
TRF No. IEC61984C
Testreport-250150-TL6-1.DOCX
VDE File No. 257500-1431-0045/250150
conductor with a minimum cross-section as
specified in Table 1, Column 2:
Minimum cross- section according to Table 1 ..... :
mm²
6.5.4.2
With regard to design and type of construction, the
protective conductor terminations are at least
equivalent to the other terminations according to
clause 6.:
N/A
A5
INTERLOCK
7.3.4
The specimens are engaged by hand over their full
engagement distance. All other contacts are wired
in series. The interlock contacts “make last and
break first”, before any other contact does.
N/A
6.7
The connector with an interlock cannot be engaged
or disengaged as long as the contacts are live.
N/A
A6
TERMINATIONS
6.6
Range of connectable conductor(s) ................... :
from: 0,14 mto: 1,5 mm²
6.6.1 a)
Test acc. to: IEC 60352-1
Wrapped connections
N/A
6.6.1 b)
Test acc. to: IEC 60352-2
Crimped connections
N/A
6.6.1 c)
Test acc. to: IEC 60352-3 or IEC 60998-2-3
Accessible insulation displacement connections
N/A
6.6.1 d)
Test acc. to: IEC 60352-4 or IEC 60998-2-3
Non-accessible insulation displacement
connections
N/A
6.6.1 e)
Test acc. to: IEC 60352-5
Press-in connections
N/A
6.6.1 f)
Test acc. to: IEC 60352-6 or IEC 60998-2-3
Insulation piercing connections
N/A
6.6.1 g)
Test acc. to: IEC 60999-1 or IEC 60999-2 or IEC
60352-7 Screwless-type clamping units
P
6.6.1 h)
Test acc. to: IEC 60999-1 or IEC 60999-2
Screw-type clamping units
N/A
6.6.1 i)
Test acc. to: IEC 60760 or IEC 61210
Flat, quick-connect terminations
N/A
Test acc. to: IEC 60068-2-20
Solder terminations
P
Other terminations, not mentioned above, acc. to
IEC standard ....................................................... :
N/A